Documentation

Division by singular matrix

Description

Select the diagnostic action to take if theProductblock detects a singular matrix while inverting one of its inputs in matrix multiplication mode.

Category:Diagnostics

Settings

Default:none

none

金宝app®software takes no action.

warning

Simulink software displays a warning.

error

Simulink software terminates the simulation and displays an error message.

Tips

For models referenced in Accelerator mode, Simulink ignores theDivision by singular matrixparameter setting if you set it to a value other thanNone.

You can use the Model Advisor to identify referenced models for which Simulink changes configuration parameter settings during accelerated simulation.

  1. In the Simulink Editor, in theModelingtab, click模型的顾问,然后单击OK.

  2. SelectBy Task.

  3. Run theCheck diagnostic settings ignored during accelerated model reference simulationcheck.

Command-Line Information

Parameter:CheckMatrixSingularityMsg
Value:'none'|'warning'|'error'
Default:'none'

Recommended Settings

Application Setting
Debugging No impact
Traceability No impact
Efficiency No impact
Safety precaution error

Related Topics